High voltage · Medium voltage
Medium voltage cable from 2 kV to 35 kV.
Shielded cable between 2 kV and 35 kV, reviewed on insulation wall, shield type, jacket condition and the paper that travels with the reel.
Medium voltage starts where ordinary building wire stops. Above 2 kV the conductor is wrapped in semiconducting layers, a heavy insulation wall and a metallic shield, then jacketed, because at those levels the electric field has to be controlled rather than simply contained. That construction is what a buyer reads first.
A lot of this cable arrives with a story attached: a plant upgrade, a padmount change-out, a service rebuilt after a fault. The story matters less than the records and the cut ends. Both are checked before anyone talks about copper weight, and neither improves with a tidy coil.
Buy quote request
Tell us what you have
Type, conductor, voltage class and how much is on hand. Photos can follow by text or email. A buyer reviews the lot before anyone talks about money.
Prefer to talk it through? 954-740-1983 · saleselectricalbuyers@gmail.com
01 Build
Reading the insulation and shield
The conductor is covered by a thin semiconducting strand shield, then the insulation, then a semiconducting insulation shield. Those two layers are the reason medium voltage cable cannot be judged like building wire: nick the outer semi-con and the cable develops a stress point that will fail in service. A buyer looks at the cut end for a clean, square cut with the layers still concentric.
Over the insulation shield sits the metallic shield, either copper tape applied helically or a wire shield with a counter-helix. Tape shields are lighter and easier to handle; wire shields tolerate more flexing and are common on feeder and riser work. The jacket is the moisture barrier, and a split or chalky jacket matters more here than on a 600 V reel.
| Shield | Typical use | What it changes |
|---|---|---|
| Copper tape | Distribution feeders | Light, dents easily, cut square |
| Wire shield | Riser and feeder | Flex tolerant, heavier reel |
| Lead sheath | Legacy paper cable | Handling plan before any cut |
| Wire armour | Plant and industrial | Armour condition decides reuse |
02 Ends
The cut ends decide more
Every installed medium voltage cable is terminated at both ends, and the way it was terminated leaves a mark. A cable cut back neatly, with the semi-con step visible and the shield still bonded, is easier to re-terminate than one sawn off with a frayed tape shield. Photograph both ends before anything is coiled.
Moisture is the other end issue. An open end that stood in a vault or a wet duct wicks water under the jacket and along the shield, and the damage is not visible from outside. Ends that were capped, taped or heat-shrunk closed tell a buyer that somebody expected the cable to be used again.
Photograph cut ends square-on, in daylight, with the reel tag in frame. One clear image of the layers saves a site visit.
03 Paperwork
Test history carries weight
Factory test certificates, the after-installation test sheet and any maintenance records matter more on this class of cable than on any other. They say the insulation was sound when it was made, sound when it was energised and monitored since. Without them, a reel is reviewed as unknown condition however good the jacket looks.
The same paperwork answers the isolation question. A buyer needs to know the circuit was de-energised, locked out, proved dead and discharged before the cable was disconnected, and who confirmed it. A written isolation record and a named responsible person are what turn removed cable into material that can change hands. The medium voltage safety guide sets out the steps that come first.
04 Handling
Footage, drums and loading
Length comes from the tag first, then the wrap count, then weight against a known construction. Reels that have been re-reeled lose the factory length mark, and a buyer will measure rather than accept a guess. Drum condition matters too: a steel drum dragged across a yard may not survive a crane lift.
Reel trailers are the better method for anything still on a drum. A forklift lifting by the drum edge dents the flange and can spill the wrap, and a reel dropped from a height is a reel with a cracked jacket and a bent conductor. Ask for the loading method before the day.
- Keep the drum banded and the tag attached until the lot is reviewed.
- Say whether a crane, reel trailer or forklift is available on site.
- Note any reel that has stood outdoors, and for how long.
- Do not cut a long remainder into shorter pieces to make it easier to move.
FAQ Seller questions
What sellers ask before they send a list
Answers describe how the buying desk works. They are not an offer, a rate or a promise of purchase.
Can medium voltage cable be reused after removal?
Sometimes, and the decision rests on the ends, the test history and how it was stored. Cable cut back cleanly and kept dry on a drum is reviewed as a candidate for re-termination. Cable with water in the shield or a crushed jacket is reviewed for copper recovery instead.
Which voltage class do you need to know?
The class printed on the jacket or tag, such as 5 kV, 15 kV, 25 kV or 35 kV. The class sets the insulation wall thickness and the termination kit, so it decides what the cable can be used for. If the print is gone, measure the wall and send a photo.
Why do you ask about the semi-con layers?
Because they show how the cable was cut and handled. A clean step with intact semi-con suggests careful removal. Torn or missing semi-con at the end means the cable needs a longer cut-back before it can be terminated, and that reduces the usable length.
Is a reel with no test records still reviewed?
Yes, but as unknown condition. The construction can be identified, the length measured and the ends inspected. What cannot be proven is the insulation history, so the lot is described that way and handled accordingly rather than assumed sound.
How should a removed run be prepared?
Leave it on the drum if it came on one, cap or tape the ends, keep the tag with the reel and photograph both ends and the jacket print. Coiling a long shielded run by hand introduces bends the cable will not forget.